Changelog
v1.0¶
Initial version
v2.0¶
- Overhauled the graph interface to be more dynamic
- Reorganized the settings window to clarify which settings belong to which section
- Added sample holder tool
v2.1¶
- Added Voc overvoltage
- Added option for multiple chambers in Sample holder tool
- Added "Channel Current" to settings window
- Allowed option to disable "Voltage Homing" in the config file
v2.2¶
- UI Overhaul of the summary table
- Now supports grouping
- Added right-click option to quickly access data files
- API v0.1 added
- Added "Save Settings" and "Load Settings" option to sample holder tool
- Removed the TrackInterval setting
v2.2.1¶
- API updated to v0.2
- UI update for the load settings wizard
v2.2.2¶
- API updated to v0.3
- Added JV parameters to tracking graph
v2.2.3¶
- API updated to v0.4
- Added option to measure Irradiance from a sensor. The values are saved in the tracking file
v2.3.0 - 2025-10-14¶
- Updated the sensor manager to allow custom sensors
- Added Day-night cycling feature
- API updated to v0.4.1
- Changed JV graph selection from radio buttons to tabs
- Restructured some internal data structures for improved memory performance
- Added temperature sensor selection to device settings.
v2.3.1 - 2025-10-18¶
- New: Environments
- Sensors can be combined into environments
- Channels can select an associated environment. All environmental parameters are saved in the device's data files
- Removed selection of temperature sensor, it is now integrated in environments
- Removed option of "From sensor" from light source, it is now integrated in environments
- Clarified the "Mode" window
v2.3.2 - 2025-10-23¶
- Added crash recovery feature
- Added suspend feature
- Temporarily removed pause function
- Improved graph performance to reduce CPU load
- Fixed 20V not working properly
v2.3.3 - 2025-10-27¶
- Fixed Forward Only not working
- Settings auto-selected channel when opened now considers the current user as well
- Temporarily removed the "voltage homing" feature
v2.3.4 - 2025-11-20¶
- Sensors from chambers are now grouped together in the sensor manager
- Added x-axis range selection
- New version of Day-Night cycling
- Improved algorithm
- User-friendly sensor selection
- Updated API to v0.4.2
- Added
GetEnvironmentsto API - Added
SetChannelEnvironmentto API
- Added
v2.3.5 - 2026-01-13¶
- Updated API to v0.5.0
- Added day-night cycling per channel
- Previous version still available by setting the "User Global" option
- The settings window has been slightly rearranged to accommodate the new feature
- Added option to select algorithm in night (previously was forced to open-circuit)
- Added option to allow JV during night time
- Added additional Day/Night column to summary table
- Added Temperature stage control in the sensor manager. They are considered as temperature sensors
- Fixed Parameter file not taking into account the irradiance value in the settings
- Fixed some settings not being copied when using the copy channels checkbox
v2.3.6 - 2026-01-13¶
- Fixed several Day-Night cycling bugs
- Fixed constant output not showing up in day-night cycle
v2.4.0 - 2026-03-09¶
- Changed file headers to now contain all settings (see JV File).
- Most notable, the environment and day-night cycling settings are now included (if enabled)
- Legacy version is still available by setting
FileHeaderVersion = 1in the config file
- Added generic temperature and humidity sensors. Any sensor with a gain and offset can be used now.
- Added sensor data files. Sensor data is saved here, independently of any configured devices